Calibrated Reference Sensitometer and Scanning Densitometer. The darkscan duo ref is a high-precision combination of reference sensitometer and scanning densitometer in one unit. It is designed for acceptance testing as well as daily routine testing of x-ray film-screen equipment according to IEC 61223-2-1, DIN V 6868-55,... Read more
Routine Test Sensitometer and Densitometer. The darklight duo devices fulfil all requirements of the IEC 61223-2-1 and DIN 6868-2 standards for daily constancy or routine tests. The combination of both sensitometer and densitometer into one device provides ease of use, lower acquisition cost and handling... Read more
Ambient Light Meter. The MaVo_lux C Base light meter is a single-purpose device primarily for ambient light measurement. It features illumination only measurement for indoor or outdoor environments. Light measurement is performed in Class C... Read more
Medical Light and Luminance Meter. The MaVo_lux 5032B light and luminance meter was developed specifically for medical application. It features luminance and illumination measurement in a single device. Light measurement is performed in Class B... Read more
Precision Light and Luminance Meter. The MaVo_spot USB is a precision instrument for specific requirements of medical light measurement applications. It features a measuring angle of 1° (strict Class B requirement) and provides luminance measurements for distances between 1m to 1°. The MaVo_spot is equipped with a... Read more
QUART MONI_lux. The QUART MONI_lux is designed for real-time monitoring of light and ambient light conditions. The device evaluates and signals if present light conditions are suitable for critical assessment of x-ray images and if ergonomic working conditions are present. The MONI_lux can be applied in digital or... Read more
Basic kVp and Timer Meter. The meter enables non-invasive measurement of tube current and exposure time. Two Device Options are available: K2 for the normal range / K2L for the sensitive range. Exposure Time is measured in Milliseconds. The meter automatically detects AC or DC and auto-resets after each... Read more
Basic mA/mAs and Timer Meter. The meter measures the tube current of x-ray generators and calculates the product of exposure time and mA for mAs. An improved circuitry increases accuracy and reliability. The meter features automatic detection of AC / DC. A self-setting procedure eliminates the need to reset. The display... Read more
Basic mAs/kVp/Timer Meter. The meter combines two instruments into one unit: kVp and mAs in one package. The mAs section is self-resetting, and the kVp measurement is non-invasive. The meter can be used on AC or DC x-rays. It measures kVp, mA, mAS, and exposure time. The instrument case is durable ABS plastic... Read more
Real-Time mA/mAs Meter. The QUART didoMAS meters automatically set the range of measurement. No pre-setting is required for direct reading of mA, mAs, and time parameters. The meters can be used throughout the complete range of radiographic equipment including fluoroscopic or mammography exposures. The meter is powered by... Read more
Electronic Personal Dose Meter w/ Dose Rate Indicator and Alarm Function. The ED150 is a dose rate meter for the measurement of gamma radiation and X-rays for dose equivalent p(10). It features an energy-compensated Geiger-Müller-tube detector in a compact casing with a large specially shaped LC display. The meter... Read more
Compact Dose Rate Meter. The Gamma Twin is a PTB-approved dose rate meter for the measurement of gamma radiation and X-rays for ambient dose rate equivalent p*(10) and ambient dose equivalent H*(10) (local dose). It features an energy-compensated Geiger-Müller-tube detector in a compact casing with a large backlit LC... Read more
Cross Shaped Radiopaque X-Ray Ruler. Set of 440 mm “0” center cross-shaped rulers on a center aluminum pin. The center is designed to easily read all 20 graduations in all directions from the center, with no graduation overlap. The set swings open for use and closes for storage in the case. The base ruler has... Read more
Direct Electronic X-Ray Ruler for Field and Fan-Beam Measurement. The QUART nonius is an easy-to-use and very sophisticated measuring instrument to verify the size and geometrical properties of X-ray fields. It can also be used to analyze characteristics of fanned X-ray beams as used in CT or dental panoramic X-rays... Read more
Routine Test Dosemeter for Mammography QA/QC 25-35 kV. The QUART dido/time meters are designed for straightforward dose/dose reference measurements as required in x-ray routine QA/QC. Routine tests are usually carried out in regular intervals to ensure the adequate performance of X-ray equipment. The QUART dido/time... Read more
Routine Test Dosemeter for X-Ray QA/QC 50-150 kV. The QUART dido/time meters are designed for simple and straight-forward dose/dose reference measurements as required in x-ray routine QA/QC. Routine tests are usually carried out in regular intervals to ensure the adequate performance of x-ray equipment. The QUART... Read more
Dosemeter Series for X-Ray Service and QA in Mammography. QUART didoEASY M, Art. 11116, Basic Configuration QUART didoEASY+ M, Art. 11116+, Added kV Measurement QUART didoEASY++ M, Art. 11116++, Added kV and Direct-HVL Measurement The QUART didoEASY meters are designed for users who emphasize high precision in... Read more
Dosemeter Series for X-Ray Service and QA in R&F and Dental. QUART didoEASY R, Art. 11115, Basic Configuration QUART didoEASY+ R, Art. 11115+, Added kV Measurement QUART didoEASY++ R, Art. 11115++, Added kV and Direct-HVL Measurement The QUART didoEASY meters are designed for users who emphasize high precision in... Read more