NL +31 24 648 86 88 NL  
BE +32 3 309 32 09 BE  
[email protected]
en
  • Nederlands
  • English
  • Français
Medical
Products
  • Radiotherapy
  • Diagnostic Imaging
  • Radiation Safety
  • Nuclear Medicine
  • Patient Positioning Solutions
  • Blood irradiation indicators
  • Dosimetry
  • Gafchromic film QA
  • Miscellaneous & accessories
  • Plan verification
  • Proton
  • QA Phantoms
  • QA Measurement systems
  • QA Measurement Systems
  • Analysis software
  • Blood irradiation indicators
  • Gafchromic Film QA
  • QA phantoms
  • Training phantoms
  • Contamination monitoring
  • Detectors & miscellaneous
  • Doorway & environmental monitoring
  • Dose rate monitoring
  • Software
  • Personal dosimetry
  • Neutron detectors
  • QA sources
  • QA Phantoms
  • Detectors
  • Alpha, beta & gamma spectrometry
  • Samplers / counters
  • Stack & air monitoring
  • Sterilization irradiation indicators
Service
Partners
Resources
News and events
Vacancies
Contact
Nieuws

PEO presenteert de nieuwe generatie ISP Gafchromic EBT3

PEO presenteert de nieuwe generatie ISP Gafchromic EBT3 radiochromatische dosimetrie film voor externe bestraling

ISP Gafchromic heeft de introductie van de EBT3 voor september 2011 aangekondigd. De nieuwe generatie radiochromatische film voor het weergeven van stralingsdosis brengt een aantal extra voordelen met zich mee. Zo geeft het symmetrisch ontwerp de mogelijkheid om de film vanaf beide zijden te scannen. EBT3 is vooraf gemarkeerd, wat automatische uitlijning met het gebruik van FilmQA Pro software mogelijk maakt. Bovendien heeft de EBT3 een matte polyester laag welke de vorming van Newton’s Rings voorkomt.

voordelen

  • symmetrische structuur, gemakkelijk in gebruik
  • mat polyester voorkomt formatie van Newton’s Rings
  • vooraf gemarkeerd

toepassingsgebied

  • intensiteitsgemoduleerde radiotherapie QA (IMRT)
  • externe bestraling radiotherapie

kenmerken

  • breed dosis bereik, 1cGy tot > 40 Gy
  • veranderingen in dichtheid stabiliseren snel
  • energie onafhankelijke dosis respons
  • vermindert scattering
  • bijna gelijk aan weefsel
  • uniformiteit van de film beter dan +/- 3% in de dosis
  • hoge ruimtelijke resolutie (5000 dpi)
  • hogere dichtheid dan EBT2, mat polyester licht troebel
  • geen donkere kamer nodig
  • te gebruiken met water fantomen, onder te dompelen in water (waterbestendig)
  • bestand tegen temperaturen tot 70° C
  • ontwikkelt zich direct zonder verwerkingsproces
  • ondersteunt alle belangrijke RT-technologieën
  • verkrijgbaar in twee formaten: 8” x 10” (25 per doos) en 14” x 17” (10 per doos)
    aangepaste formaten op bestelling

Wilt u meer weten over de ISP Gafchromic EBT3?
Bekijk de datasheet (

) of neem contact op met PEO tel. 024 648 86 88.

Bekijk tevens de vergelijking met de EBT2 (  ).

EBT3 doos

Productie van EBT3 film

More info?
Contact us
This message is from our archive and may contain formatting errors.
Share this article

https://peomedical.com/medical/nieuws/peo-presenteert-de-nieuwe-generatie-isp-gafchromic-ebt3/

Copy the link
Email WhatsApp WhatsApp LinkedIn
Contact
NL +31 24 648 86 88
BE +32 3 309 32 09
[email protected]
Havenweg 16, 6603 AS Wijchen
Leonardo da Vincilaan 19A/8, 1831 Diegem
Go to the contact page
ISO 9001
Call-back request

    Your information





    Supply conditions Privacy policy
    PEO B.V. © 2026 All Rights Reserved

    Go to gotopeo.com

    Products
    • Radiotherapy
    • Diagnostic Imaging
    • Radiation Safety
    • Nuclear Medicine
    • Patient Positioning Solutions
    • Blood irradiation indicators
    • Dosimetry
    • Gafchromic film QA
    • Miscellaneous & accessories
    • Plan verification
    • Proton
    • QA Phantoms
    • QA Measurement systems
    • QA Measurement Systems
    • Analysis software
    • Blood irradiation indicators
    • Gafchromic Film QA
    • QA phantoms
    • Training phantoms
    • Contamination monitoring
    • Detectors & miscellaneous
    • Doorway & environmental monitoring
    • Dose rate monitoring
    • Software
    • Personal dosimetry
    • Neutron detectors
    • QA sources
    • QA Phantoms
    • Detectors
    • Alpha, beta & gamma spectrometry
    • Samplers / counters
    • Stack & air monitoring
    • Sterilization irradiation indicators
    Service
    Partners
    Resources
    News and events
    Vacancies
    Contact

    English
    • Nederlands
    • English
    • Français

    NL +31 24 648 86 88
    BE +32 3 309 32 09
    [email protected]

    LinkedIn

    Choose your cookie preferences. To provide the best experiences, we use cookies, among other things, to store and/or access device information. By consenting to these cookies we can process certain data on this site. If you do not give permission, this may have a negative effect on the operation.

    Functional Active by default
    The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service expressly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication via an electronic communications network.
    Statistics
    The technical storage or access used solely for statistical purposes.
    Marketing
    The technical storage or access is required to create user profiles to send advertisements, or to track the user on a website or across multiple websites for similar marketing purposes.