NL +31 24 648 86 88 NL  
BE +32 3 309 32 09 BE  
[email protected]
en
  • Nederlands
  • English
  • Français
Medical
Products
  • Radiotherapy
  • Diagnostic Imaging
  • Radiation Safety
  • Nuclear Medicine
  • Patient Positioning Solutions
  • Blood irradiation indicators
  • Dosimetry
  • Gafchromic film QA
  • Miscellaneous & accessories
  • Plan verification
  • Proton
  • QA Phantoms
  • QA Measurement systems
  • QA Measurement Systems
  • Analysis software
  • Blood irradiation indicators
  • Gafchromic Film QA
  • QA phantoms
  • Training phantoms
  • Contamination monitoring
  • Detectors & miscellaneous
  • Doorway & environmental monitoring
  • Dose rate monitoring
  • Software
  • Personal dosimetry
  • Neutron detectors
  • QA sources
  • QA Phantoms
  • Detectors
  • Alpha, beta & gamma spectrometry
  • Samplers / counters
  • Stack & air monitoring
  • Sterilization irradiation indicators
Service
Partners
Resources
News and events
Vacancies
Contact
Industrie & transport

Ludlum Model 9DP handmeter, hoge druk ionisatiekamer

Ludlum Model 9DP handmeter, hoge druk ionisatiekamer voor het meten gamma en röntgenstraling

Nieuw ontwerp, geheel digitaal, Ludlum Model 9DP handmeter, met hoge druk ionisatiekamer, biedt nauwkeurige dosis(tempo) metingen van gamma en röntgenstraling.

De 9DP geeft standaard dosistempo in combinatie met dosis of de hoogst gemeten piekwaarde, vanaf de inschakeling van de 9DP. Alle geregistreerde data worden in csv-formaat naar een ingeplugde standaard USB stick geschreven, voor gemakkelijk gebruik met spreadsheet of database programma.

voordelen

  • groot 8,9 cm scherm (256 kleuren) op afstand afleesbaar
  • kleurenscherm, in zonlicht afleesbaar
  • USB poort voor datalog via USB stick en aanpassing parameter via toetsenbord
  • hoge druk ionisatiekamer met leegloop functie (voor veilig transport)
  • 2 eenheden in één scherm: dosistempo gecombineerd met dosis of piekmeting

toepassingsgebied

Gebruik in omgevingen waar precieze dosis(tempo) is vereist, bijvoorbeeld bij:

  • medische toepassingen (lekstraling)
  • laboratorische toepassingen (controle)
  • industriële toepassingen (veiligheid)

kenmerken

  • meting van gamma en röntgen boven 25 keV, bèta boven 1 MeV
  • Sv/h eenheden: 0-5 µSv/h, 0-50 µSv/h, 0-500 µSv/h, 0-5 mSv/h, 0-50 mSv/h
  • responstijd: 5 seconden in laagste bereik tot 2 seconden in hoogste bereik (10% tot 90%)
  • opwarm tijd < 1 minuut wanneer instrument gelijk is aan omgevingstemperatuur
  • kamer volume 230 cc onder druk tot 8 atm (117 psi)
  • minimale uitlezing: 0.01 µSv/h
  • nauwkeurigheid: +/- 10%
  • auto zeroing & ranging
  • auto LCD achtergrondverlichting
  • dosistempo, dosis & piek meting
  • data opslag met tijdsaanduiding
  • USB connectiviteit
  • alarm: geluid en op scherm
  • oplaadbare batterijen voor 12 – 30 uur gebruik per lading

Ludlum Model 9DP-1 voor gepulseerde velden

Ook verkrijgbaar, de non hazmat Ludlum Model 9DP-1 met lage druk kamer.
Speciaal design voor het meten van gepulseerde velden.

Wilt u meer weten over de Ludlum Model 9DP?

Neem contact op met PEO tel. 024 648 86 88.

{swf}M9DP|197|200|{/swf}Klik & beweeg

8,9 cm kleurenscherm

USB toetsenbord connectiviteit

More info?
Contact us
This message is from our archive and may contain formatting errors.
Partner

...


Go to partner
Share this article

https://peomedical.com/medical/industrie-transport/ludlum-model-9dp-handmeter-hoge-druk-ionisatiekamer/

Copy the link
Email WhatsApp WhatsApp LinkedIn
Contact
NL +31 24 648 86 88
BE +32 3 309 32 09
[email protected]
Havenweg 16, 6603 AS Wijchen
Leonardo da Vincilaan 19A/8, 1831 Diegem
Go to the contact page
ISO 9001
Call-back request

    Your information





    Supply conditions Privacy policy
    PEO B.V. © 2026 All Rights Reserved

    Go to gotopeo.com

    Products
    • Radiotherapy
    • Diagnostic Imaging
    • Radiation Safety
    • Nuclear Medicine
    • Patient Positioning Solutions
    • Blood irradiation indicators
    • Dosimetry
    • Gafchromic film QA
    • Miscellaneous & accessories
    • Plan verification
    • Proton
    • QA Phantoms
    • QA Measurement systems
    • QA Measurement Systems
    • Analysis software
    • Blood irradiation indicators
    • Gafchromic Film QA
    • QA phantoms
    • Training phantoms
    • Contamination monitoring
    • Detectors & miscellaneous
    • Doorway & environmental monitoring
    • Dose rate monitoring
    • Software
    • Personal dosimetry
    • Neutron detectors
    • QA sources
    • QA Phantoms
    • Detectors
    • Alpha, beta & gamma spectrometry
    • Samplers / counters
    • Stack & air monitoring
    • Sterilization irradiation indicators
    Service
    Partners
    Resources
    News and events
    Vacancies
    Contact

    English
    • Nederlands
    • English
    • Français

    NL +31 24 648 86 88
    BE +32 3 309 32 09
    [email protected]

    LinkedIn

    Choose your cookie preferences. To provide the best experiences, we use cookies, among other things, to store and/or access device information. By consenting to these cookies we can process certain data on this site. If you do not give permission, this may have a negative effect on the operation.

    Functional Active by default
    The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service expressly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication via an electronic communications network.
    Statistics
    The technical storage or access used solely for statistical purposes.
    Marketing
    The technical storage or access is required to create user profiles to send advertisements, or to track the user on a website or across multiple websites for similar marketing purposes.